Прегледај по Аутор "Filipović, Vojislav "
Сада се приказује 1 - 5 од 5
Резултати по страници
Опције сортирања
- СтавкаCOMPARISON OF TWO MATHEMATICAL MODELS FOR CONTROL SYSTEM OF LEVEL IN CONDENSER OF TURBINE IN THE THERMAL POWER PLANT(International ConferenceProcess Technology And Environmental Protection, 2011-12) Prodanović, Saša; Nedić, Novak; Filipović, VojislavThis paper shows large importance of adequate mathematical modeling of system. Control system of level in condenser of turbine in thermal power plant Gacko is taken into exploration. Here it was presented in two ways, as first-order system and second-order system. Their analysis and comparison were carried out after auto-tuning of PID (proportional-integral-derivative) controller using relay feedback test simulation. Obtained parameters of PID controller were applied into both variations of the system block diagram and its responses have been utilized for giving evaluation of researched models.
- СтавкаEnergy saving in the power plants using automatic control(2011) Nedić, Novak; Filipović, Vojislav; Prodanović, SašaThe constant striving to reduce energy consumption leads toward introduction of strategies, which can enable it. In this paper, the strategy which includes frequency regulators into control system of condensate level in condenser of turbine in thermal power plant Gacko is proposed. Properly tuned PID (proportional-integral-derivative) controllers are precondition for appropriate process control. Therefore, the mathematical model of this system is formed and simulations of auto-tuning of PID controllers, using ideal relay and saturation relay as nonlinearity, are carried out. Static load disturbance are considered too, because of its adverse effect both directly on the object, and in auto-tuning process, which causes errors in determining of PID regulator’s parameters. The justification of the introduction of frequency regulators has been confirmed by calculation of energy saving. Its feasibility was proved through simulation of the functioning of the entire control system of level in condenser, based on consideration of characteristic parameters of system response.
- СтавкаImproved Auto-tuning PID Controller of Level in Condenser of Turbine in Thermal Power Plant Using Saturation-relay Feedback(Faculty of Electronic Engineering; Faculty of Mechanical Engineering, University of Niš, 2010) Prodanović, Saša; Nedić, Novak; Filipović, VojislavProperly tuned controllers should ensure correct and unobstructed functioning of the system, i.e. process. Using ideal relay as nonlinearity in process of auto-tuning gives significant errors in estimates of the ultimate gain and ultimate period. In this paper mentioned lack is overcomed by introduction saturation relay, where control system of condensate level in condenser of turbine in thermal power plant Gacko is used as a model. Due to the constant striving to reduce energy consumption, above settings are implemented in the system for which is proposed strategy which provides energy savings, i.e. includes frequency regulators.
- СтавкаModified approach to distillation column control(Association of the Chemical Engineers of Serbia, 2017) Prodanović, Saša; Nedić, Novak; Filipović, Vojislav ; Dubonjić, LjubišaThis paper contains methodology research for forming the control algorithm for a distillation column, modeled as TITO (two-input two-output) process. Its modified form was obtained by connecting the two parts, and this combination hasn't been applied for such a industrial plant, until now. These parts include: a simplified decoupler which was first designed and decentralized PID controller obtained using D-decomposition method for such decoupled process. The decoupler was designed in order to make process become diagonal, and parameters of PID controllers are defined for the two SISO (single-input single-output) processes starting from relation between IE (integral error) criterion and integrator gain, taking into account desired response characteristics deriving from technological requirements of controlled plant. Their connecting provides centralized control. Analysis of the processes responses, obtained by the proposed algorithm and their comparison with the results from the literature, were performed after the completion of the simulations. The proposed approach to the centralized controller design, beside its simplicity of usage and flexibility in achieving diversity of process dynamic behavior, gives better response characteristics, in comparison with existing control algorithms for distillation column in the literature.
- СтавкаReduced Energy Cost through the Furnace Pressure Control in Power Plants(2012) Filipović, Vojislav ; Nedić, Novak ; Prodanović, SašaMaintaining pressure in the boiler’s furnace is one of the key requirements for proper combustion in steam boilers in thermal power plants. This paper proposes a control strategy that eliminates flap in the channel for the output gases. This is achieved by applying the frequency regulator for asynchronous motor speed control. Reference value for the frequency regulator is obtained through the PI controller. Special attention is given to tuning of PI controller. Well-tuned PI controller with the use of frequency regulator provides significant energy savings, because asynchronous motor for ventilator of steam boiler in thermal power plants has a large power. Modification of relay feedback experiment has supported λ-tuning of controller whose two types (faster and robust) were tuned. This modification consists in: a) Replacement of relay characteristic with saturation curve, b) Fourth-order process identification with first-order process plus dead time. The methodology is illustrated by simulations.